By using a full scientific excellent administration method, great quality and fantastic religion, we get good reputation and occupied this discipline for Kinetic Friction Coefficient, Fluorescence Spectrophotometer, Hologram, Presently, we're wanting forward to even higher cooperation with abroad shoppers depending on mutual rewards. You should really feel totally free to make contact with us for more aspects.
China Wholesale photoelectric effect Factory – LADP-14 Determining Specific Charge of Electron – Advanced Model – Labor Detail:

Experiments

1. Quantitatively measure the rules of electron movement in both electric and magnetic field.

    a) Electrical deflection: electron + transversal electric field

b) Electrical focusing: electron + longitudinal electric field

c) Magnetic deflection: electron + transversal magnetic field

d) Spiral motion magnetic focusing: electron + longitudinal magnetic field

2. Determine e/m ratio of an electron and verify the polar coordinate equation of electron spiral motion.

3. Measure geomagnetic component.

The instruction manual contains comprehensive materials including experimental configurations, principles, step-by-step instructions and some experimental results. Please click Experiment Theory and Contents to find more information about this apparatus.

 

Specifications

 

Description Specifications
Filament voltage 6.3 VAC; current 0.15 A
High voltage UA2 600 ~ 1000 V
Deflecting voltage -55 ~ 55 V
Grid voltage UA1 0 ~ 240 V
Control grid voltage UG 0 ~ 50 V
magnetization current 0 – 2.4 A
Solenoid parameters
Longitudinal coil (long) length: 205 mm; inner dia: 90 mm; outer dia: 95 mm; number of turns: 1160
Transversal coil (small) length: 20 mm; inner dia: 60 mm; outer dia: 65 mm; number of turns: 380
Digital meters 3-1/2 digits
Sensitivity of electrical deflection Y: ≥0.38 mm/V; X:  ≥0.25 mm/V
Sensitivity of magnetic deflection Y: ≥0.08 mm/mA
e/m measurement error ≤5.0%

 

Parts List

 

Description Qty
Main unit 1
CRT 1
Long coil (solenoid coil) 1
Small coil (deflection coil) 2
Division screen 1
Cable 2
Instructional manual 1

Product detail pictures:

China Wholesale photoelectric effect Factory –  LADP-14 Determining Specific Charge of Electron – Advanced Model – Labor detail pictures


Related Product Guide:

Excellent 1st,and Client Supreme is our guideline to deliver the ideal provider to our prospects.Nowadays, we have been seeking our best to become certainly one of the most effective exporters in our discipline to meet shoppers more require for China Wholesale photoelectric effect Factory – LADP-14 Determining Specific Charge of Electron – Advanced Model – Labor , The product will supply to all over the world, such as: Georgia, Singapore, Libya, We follow superior mechanism to process these goods that ensure optimum durability and reliability of the goods. We follow latest effective washing and straightening processes that enable us to supply unmatched quality of items for our clients. We continually strive for perfection and all our efforts are directed towards attaining complete client satisfaction.
  • Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Odelia from Armenia - 2017.04.08 14:55
    Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Beulah from Bangladesh - 2018.12.28 15:18
    Write your message here and send it to us