China Wholesale Image Convolution Factories – LCP-9 Modern Optics Experiment Kit – Labor
China Wholesale Image Convolution Factories – LCP-9 Modern Optics Experiment Kit – Labor Detail:
Note: stainless steel optical table or breadboard not provided
Description
This experiment is a comprehensive experimental device provided by our company for physical optics laboratory in universities. It covers many fields, including applied optics, information optics, physical optics, holography and so on. The experimental system is equipped with various optical elements, adjusting bracket and experimental light source. It is easy to adjust and flexible. Many experimental projects are closely integrated with theoretical teaching. Through the operation of a complete set of experimental system, students can further understand the theory of learning in class, grasp various experimental operation methods, and cultivate positive exploration and thinking ability and practical ability. At the same time with basic experimental projects, users can build or configure more experimental projects or combinations according to their own needs.
Experiments
1. Measure lens focal length using auto-collimation method
2. Measure lens focal length using displacement method
3. Measure air refractive index by building a Michelson interferometer
4. Measure the nodal locations and focal length of a lens-group
5. Assemble a telescope and measure its magnification
6. Observe the six types of aberrations of a lens
7. Construct a Mach-Zehnder interferometer
8. Construct a Signac interferometer
9. Measure the wavelength separation of Sodium D-lines using a Fabry-Perot interferometer
10. Construct a prism spectrographic system
11. Record and reconstruct holograms
12. Record a holographic grating
13. Abbe imaging and optical spatial filtering
14. Pseudo-color encoding
15. Measure grating constant
16. Optical image addition and subtraction
17. Optical image differentiation
18. Fraunhofer diffraction
Note: An optional stainless steel optical table or breadboard (1200 mm x 600 mm) is needed for use with this kit.
Part List
| Description | Part No. | Qty |
| XYZ translation on magnetic base | 1 | |
| X-Z translation on magnetic base | 02 | 1 |
| Z translation on magnetic base | 03 | 2 |
| Magnetic base | 04 | 4 |
| Two-axis mirror holder | 07 | 2 |
| Lens holder | 08 | 2 |
| Grating/Prism table | 10 | 1 |
| Plate holder | 12 | 1 |
| White screen | 13 | 1 |
| Object screen | 14 | 1 |
| Iris diaphragm | 15 | 1 |
| 2-D adjustable holder (for light source) | 19 | 1 |
| Sample stage | 20 | 1 |
| Single-sided adjustable slit | 27 | 1 |
| Lens group holder | 28 | 1 |
| Standing ruler | 33 | 1 |
| Direct measuring microscope holder | 36 | 1 |
| Single-sided rotary slit | 40 | 1 |
| Biprism holder | 41 | 1 |
| Laser holder | 42 | 1 |
| Ground glass screen | 43 | 1 |
| Paper clip | 50 | 1 |
| Beam expander holder | 60 | 1 |
| Beam expander (f=4.5, 6.2 mm) | 1 each | |
| Lens (f=45, 50, 70, 190, 225, 300 mm) | 1 each | |
| Lens (f=150 mm) | 2 | |
| Doublet Lens (f=105 mm) | 1 | |
| Direct measurement microscope (DMM) | 1 | |
| Plane mirror | 3 | |
| Beam splitter (7:3) | 1 | |
| Beam splitter (5:5) | 2 | |
| Dispersion prism | 1 | |
| Transmission grating (20 l/mm & 100 l/mm) | 1 each | |
| Composite grating (100 l/mm and 102 l/mm) | 1 | |
| Character with grid | 1 | |
| Transparent crosshair | 1 | |
| Checkerboard | 1 | |
| Small hole (dia 0.3 mm) | 1 | |
| Silver salt holographic plates (12 plates of 90 mm x 240 mm per plate) | 1 box | |
| Millimeter ruler | 1 | |
| Theta modulation plate | 1 | |
| Hartman diaphragm | 1 | |
| Small object | 1 | |
| Filter | 2 | |
| Spatial filter set | 1 | |
| He-Ne laser with power supply | (>1.5 mW@632.8 nm) | 1 |
| Low-pressure Mercury bulb with housing | 20 W | 1 |
| Low-pressure Sodium bulb with housing and power supply | 20 W | 1 |
| White light source | (12 V/30 W, variable) | 1 |
| Fabry-Perot interferometer | 1 | |
| Air chamber with pump and gauge | 1 | |
| Manual counter | 4 digits, counts 0 ~ 9999 | 1 |
Note: a stainless steel optical table or breadboard (1200 mm x 600 mm) is needed for use with this kit.
Product detail pictures:
Related Product Guide:
In an effort to provide you advantage and enlarge our business enterprise, we even have inspectors in QC Staff and assure you our greatest provider and item for China Wholesale Image Convolution Factories – LCP-9 Modern Optics Experiment Kit – Labor , The product will supply to all over the world, such as: Mali, Austria, Lesotho, We taking advantage of experience workmanship, scientific administration and advanced equipment, ensure the product quality of production, we not only win the customers' faith, but also build up our brand. Today, our team is committed to innovation, and enlightenment and fusion with constant practice and outstanding wisdom and philosophy, we cater to the market demand for high-end goods, to do experienced products and solutions.