China Wholesale Giant Magnetoresistance Effect Quotes – LADP-3 Microwave Electron Spin Resonance Apparatus – Labor
China Wholesale Giant Magnetoresistance Effect Quotes – LADP-3 Microwave Electron Spin Resonance Apparatus – Labor Detail:
Experiments
1. Study and acknowledge electron spin resonance phenomenon.
2. Measure Lande’s g-factor of DPPH sample.
3. Learn how to use microwave devices in EPR system.
4. Understand standing wave by changing resonant cavity length and determine waveguide wavelength.
5. Measure standing wave field distribution in resonant cavity and determine waveguide wavelength.
Specifications
Microwave System | |
Short-circuit piston | adjustment range: 30 mm |
Sample | DPPH powder in tube (dimensions: Φ2×6 mm) |
Microwave frequency meter | measurement range: 8.6 GHz ~ 9.6 GHz |
Waveguide dimensions | inner: 22.86 mm × 10.16 mm (EIA: WR90 or IEC: R100) |
Electromagnet | |
Input voltage and accuracy | Max: ≥ 20 V, 1% ± 1 digit |
Input current range and accuracy | 0 ~ 2.5 A, 1% ± 1 digit |
Stability | ≤ 1×10-3+5 mA |
Strength of magnetic field | 0 ~ 450 mT |
Sweep Field | |
Output voltage | ≥ 6 V |
Output current range | 0.2 ~ 0.7 A |
Phase adjustment range | ≥ 180° |
Scan output | BNC connector, saw-tooth wave output 1~10 V |
Solid State Microwave Signal Source | |
Frequency | 8.6 ~ 9.6 GHz |
Frequency drift | ≤ ± 5×10-4/15 min |
Working voltage | ~ 12 VDC |
Output power | > 20 mW under equal amplitude mode |
Operation mode & parameters | Equal amplitude |
Internal square-wave modulationRepetition frequency: 1000 HzAccuracy: ± 15%Skewness: < ± 20% | |
Waveguide dimensions | inner: 22.86 mm × 10.16 mm (EIA: WR90 or IEC: R100) |
Parts List
Description | Qty |
Main Controller | 1 |
Electromagnet | 1 |
Support Base | 3 |
Microwave System | 1 set (including various microwave components, source, detector, etc) |
DPPH Sample | 1 |
Cable | 7 |
Instructional Manual | 1 |
Product detail pictures:

Related Product Guide:
We have probably the most state-of-the-art output equipment, experienced and qualified engineers and workers, recognized good quality manage systems plus a friendly skilled income workforce pre/after-sales support for China Wholesale Giant Magnetoresistance Effect Quotes – LADP-3 Microwave Electron Spin Resonance Apparatus – Labor , The product will supply to all over the world, such as: Bulgaria, Provence, Madras, We are trying our best to make more customers happy and satisfied. we sincerely hope to establish a good long-term business relationship with your esteemed company thought this opportunity,based on equal, mutual beneficial and win win business from now till the future.

The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!

Write your message here and send it to us