Welcome to our websites!
section02_bg(1)
head(1)

China Wholesale Fluorescence Spectrophotometer Manufacturers – Apparatus for Determining Planck’s Constant – Advanced Model – Labor

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We normally think and practice corresponding on the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and also the living for Fabry Perot Interferometer, Holography Experiment, Nmr, Welcome buddies from all over the earth come to visit, tutorial and negotiate.
China Wholesale Fluorescence Spectrophotometer Manufacturers – Apparatus for Determining Planck’s Constant – Advanced Model – Labor Detail:

Features

 

  • Manual or auto measurement modes

  • Integrated structure and easy to operate

  • No crosstalk between spectral lines

  • Built-in data acquisition card with software for PC use via USB port

Introduction

It used for determining Planck’s constant is used to demonstrate the photoelectric effect, The filter adopts high-grade integrated operational amplifier and special circuit design, high-performance photoelectric tube, and the dial is a filter structure with novel design and complete functions.

Photocell sensitivity ≥ 1mA / LM, dark current ≤ 10A; zero drift ≤ 0.2% (full scale reading, 10a gear, after 20 minutes of preheating, measured within 30 minutes under normal environment); 3.5-bit LED display, the minimum current display is 10a, the minimum voltage display is 1mV, so the “zero current method” or “compensation method” can be used to accurately measure the cut-off voltage

 

 

Specifications

 

Description Specifications
Wavelength of filters 365 nm, 405 nm, 436 nm, 546 nm, 577 nm
Size of apertures 2 mm, 4 mm, 8 mm, 10 mm, 12 mm
Light source 50 W Mercury lamp
Photocell Wavelength range: 340 ~ 700 nm
Cathode sensitivity: ≥1 µA (-2 V ≤ UKA ≤ 0 V)
Anode dark current: ≤5×10-12 A (-2 V ≤ UKA ≤ 0 V)
Current range 10-7 ~ 10-13 A, 3-1/2 digit display
Voltage range I: -2 ~ +2 V; II: -2 ~ +20 V, 3-1/2 digit display, stability ≤0.1 %
Zero drift < ±0.2% of full scale (for scale 10-13 A) within 30 minutes after warm-up
Measurement method Zero current method and compensation method
Measurement error 3%

 

Parts List

 

Description Qty
Main Unit 1
Electric Control Unit 1
Special BNC Cable 2
USB Cable 1
Software CD 1
Power Cord 1
Instructional Manual 1

Product detail pictures:

China Wholesale Fluorescence Spectrophotometer Manufacturers –  Apparatus for Determining Planck’s Constant – Advanced Model – Labor detail pictures


Related Product Guide:

We've been convinced that with joint efforts, the enterprise between us will bring us mutual benefits. We could guarantee you item excellent and aggressive price tag for China Wholesale Fluorescence Spectrophotometer Manufacturers – Apparatus for Determining Planck’s Constant – Advanced Model – Labor , The product will supply to all over the world, such as: Germany, Toronto, Berlin, Facing fierce global market competition, we have launched the brand building strategy and updated the spirit of "human-oriented and faithful service", with an aim to gain global recognition and sustainable development.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Carol from Greece - 2018.12.14 15:26
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By David from Czech - 2017.12.19 11:10
    Write your message here and send it to us