China Wholesale Fluorescence Spectrometer Suppliers – LADP-1A Experimental System of CW NMR – Advanced Model – Labor

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We are going to dedicate ourselves to providing our esteemed buyers together with the most enthusiastically thoughtful products and services for Photoelectric Characteristic, Lambert"s Cosine Law, Air Heat Ratio, We are anticipating to cooperate with you around the basis of mutual added benefits and common development. We are going to never disappoint you.
China Wholesale Fluorescence Spectrometer Suppliers – LADP-1A Experimental System of CW NMR – Advanced Model – Labor Detail:

 

Description 

Optional part:Frequency meter, self prepared part oscilloscope

This experimental system of continuous-wave nuclear magnetic resonance (CW-NMR) consists of a high homogeneity magnet and a main machine unit. A permanent magnet is used to provide a primary magnetic field superimposed by an adjustable electromagnetic field, generated by a pair of coils, to allow a fine adjustment to the total magnetic field and to compensate magnetic field fluctuations caused by temperature variations.

Because only small magnetizing current is needed for relatively low electromagnetic field, the heating problem of the system is minimized. Thus, the system can be operated continuously for several hours. It is an ideal experimental instrument for advanced physics laboratories.

Experiment

1. To observe the nuclear magnetic resonance (NMR) phenomenon of hydrogen nuclei in water and compare the influence of paramagnetic ions;

2. To measure the parameters of hydrogen nuclei and fluorine nuclei, such as spin magnetic ratio, Lande g factor, etc.

Specifications

Description

Specification

Measured nucleus H and F
SNR > 46 dB (H-nuclei)
Oscillator frequency 17 MHz to 23 MHz, continuously adjustable
Area of magnet pole Diameter: 100 mm; spacing: 20 mm
NMR signal amplitude (peak to peak) > 2 V (H-nuclei); > 200 mV (F-nuclei)
Homogeneity of magnetic field better than 8 ppm
Adjustment range of electromagnetic field 60 Gauss
Number of coda waves > 15

 

 


Product detail pictures:

China Wholesale Fluorescence Spectrometer Suppliers –  LADP-1A Experimental System of CW NMR – Advanced Model – Labor detail pictures


Related Product Guide:

Our items are commonly identified and trusted by people and can fulfill repeatedly altering economic and social wants of China Wholesale Fluorescence Spectrometer Suppliers – LADP-1A Experimental System of CW NMR – Advanced Model – Labor , The product will supply to all over the world, such as: Mecca, Poland, Ottawa, Our solutions have national accreditation requirements for qualified, good quality items, affordable value, was welcomed by individuals all over the world. Our goods will continue to improve inside the order and appear forward to cooperation with you, Really should any of those items be of interest to you, please letus know. We will be satisfied to provide you a quotation up on receipt of the detailed needs.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Rae from Ecuador - 2017.02.18 15:54
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Naomi from Philippines - 2018.12.30 10:21
    Write your message here and send it to us