Assume full obligation to meet all demands of our customers; accomplish ongoing advancements by promoting the advancement of our customers; become the final permanent cooperative partner of clientele and maximize the interests of shoppers for Stefan-Boltzmann Law, Microwave Polarization, Photocell Characterization, Currently, we are wanting ahead to even bigger cooperation with abroad customers according to mutual positive aspects. Be sure to sense free to contact us for more details.
China Wholesale Fluorescence Spectrometer Pricelist – LB-820 UV-Vis NIR Spectrophotometer – Labor Detail:

Instrument features

 

The design of double beam optical system reduces the background interference and improves the test accuracy.

The receiver parts of the instrument are all imported devices, which ensure the high performance and stability of the instrument.

The control of the instrument (such as grating conversion, filter conversion, receiver conversion, wavelength scanning, etc.) is all controlled by the computer, and the interface is USB2.0. The connection of the instrument is simple, which greatly improves the communication speed.

The integrated optical test system software can be selected to automatically detect the visible light transmittance, direct sunlight transmittance, direct sunlight reflectance and other related parameters of building glass.

The total transmittance of solar energy and the shielding coefficient of various window glass components to solar radiation heat can be obtained by cooperating with the glass hemispherical emissivity detector.

Special sample test accessories can be selected.

The software sets the import function, which can import data in text format.

Real time measurement of sample data, test result data can be exported.

The software can run under WinXP and win7 systems.

  

Specification parameters

1. Light source: imported deuterium lamp, tungsten bromide lamp

2. Wavelength range (nm): 190-2800 (expandable to 3600nm)

3. Wavelength accuracy (nm): ± 0.5 (UV / VIS); ± 4 (NIR)

4. Wavelength repeatability (nm): ≤ 0.3 (UV / VIS); ≤ 2 (NIR)

5. Bandwidth (nm): 0.2-5 (UV-Vis), 1-20 (NIR)

6. Transmittance accuracy (% t): ± 0.3

7. Transmission specific gravity refolding (% t): ≤ 0.2

8. Stray light (% t): ≤ 0.2% t (220nm, NAI)

9. Working mode: transmittance, absorbance, reflectivity, energy

10. Software function: according to the custom of customers, the corresponding test interface function can be customized to measure the transmittance, absorbance and absolute reflection of the test sample.

11. Sampling interval: 0.1nm, 0.2nm, 0.5nm, 1nm, 1.5nm, 2nm, 5nm, 10nm

12. Photometric range: 0 ~ 2.5A

13. Baseline Flatness: ± 0.004a (200-2500nm, after preheating for 30 minutes)

14. Host interface: USB2.0

15. Dimension (mm): (shape) 830 * 600 * 260, (sample room) 120 * 240 * 200

16. Test sample specification (mm): 30 ~ 110, thickness ≤ 20

17. Weight (kg): about 65

18. Basic configuration:

UV Vis NIR spectrometer host, USB data cable, quartz cuvette, zero block, application software, supporting tools, etc. (a set of solid accessories and liquid accessories is standard)

Glass comprehensive optical test system software is optional

*Users need to provide their own computers and printers

 

Optional accessories

 

Zf820-1 integrating sphere accessories

     Double detectors with diameter of Φ 60mm, 380-2500nm

Zf820-2 solid sample measurement accessories

     Range of clamping lens: diameter: Φ 10-36mm; thickness: 0.5-10mm

Zf820-3 reflection measurement accessory

     The incident angle is 5 degrees, and the reflection spectrum is measured

 

Software

The working software of the instrument has rich test and analysis functions, which can measure the transmittance, absorbance, energy and reflectivity. It has the functions of spectrum scanning, fixed-point measurement and multi wavelength measurement

Software of glass comprehensive optical test system

According to GB / t2680-94, the software is easy to operate, convenient to import and store data, and flexible to operate, including UV calculation, visible light calculation, sunlight calculation, shielding coefficient calculation, thermal conductivity calculation in GB / t2680-94.

 

Data printing: a unique output report to meet the needs of most users. Output reports include: visible light transmittance, visible light reflectance, direct sunlight transmittance, etc.


Product detail pictures:

China Wholesale Fluorescence Spectrometer Pricelist –  LB-820 UV-Vis NIR Spectrophotometer – Labor detail pictures


Related Product Guide:

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for China Wholesale Fluorescence Spectrometer Pricelist – LB-820 UV-Vis NIR Spectrophotometer – Labor , The product will supply to all over the world, such as: Southampton, Albania, Melbourne, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to in your case of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We've been confident that we've been going to have a bright prospect and to be distributed all over the world in the years to come.
  • We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Meredith from British - 2018.07.12 12:19
    It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Audrey from Malawi - 2018.11.02 11:11
    Write your message here and send it to us