China Wholesale Ferromagnetic Resonance Factories – LADP-3 Microwave Electron Spin Resonance Apparatus – Labor
China Wholesale Ferromagnetic Resonance Factories – LADP-3 Microwave Electron Spin Resonance Apparatus – Labor Detail:
Experiments
1. Study and acknowledge electron spin resonance phenomenon.
2. Measure Lande’s g-factor of DPPH sample.
3. Learn how to use microwave devices in EPR system.
4. Understand standing wave by changing resonant cavity length and determine waveguide wavelength.
5. Measure standing wave field distribution in resonant cavity and determine waveguide wavelength.
Specifications
| Microwave System | |
| Short-circuit piston | adjustment range: 30 mm |
| Sample | DPPH powder in tube (dimensions: Φ2×6 mm) |
| Microwave frequency meter | measurement range: 8.6 GHz ~ 9.6 GHz |
| Waveguide dimensions | inner: 22.86 mm × 10.16 mm (EIA: WR90 or IEC: R100) |
| Electromagnet | |
| Input voltage and accuracy | Max: ≥ 20 V, 1% ± 1 digit |
| Input current range and accuracy | 0 ~ 2.5 A, 1% ± 1 digit |
| Stability | ≤ 1×10-3+5 mA |
| Strength of magnetic field | 0 ~ 450 mT |
| Sweep Field | |
| Output voltage | ≥ 6 V |
| Output current range | 0.2 ~ 0.7 A |
| Phase adjustment range | ≥ 180° |
| Scan output | BNC connector, saw-tooth wave output 1~10 V |
| Solid State Microwave Signal Source | |
| Frequency | 8.6 ~ 9.6 GHz |
| Frequency drift | ≤ ± 5×10-4/15 min |
| Working voltage | ~ 12 VDC |
| Output power | > 20 mW under equal amplitude mode |
| Operation mode & parameters | Equal amplitude |
| Internal square-wave modulationRepetition frequency: 1000 HzAccuracy: ± 15%Skewness: < ± 20% | |
| Waveguide dimensions | inner: 22.86 mm × 10.16 mm (EIA: WR90 or IEC: R100) |
Parts List
| Description | Qty |
| Main Controller | 1 |
| Electromagnet | 1 |
| Support Base | 3 |
| Microwave System | 1 set (including various microwave components, source, detector, etc) |
| DPPH Sample | 1 |
| Cable | 7 |
| Instructional Manual | 1 |
Product detail pictures:
Related Product Guide:
Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for China Wholesale Ferromagnetic Resonance Factories – LADP-3 Microwave Electron Spin Resonance Apparatus – Labor , The product will supply to all over the world, such as: Nepal, Jordan, Adelaide, Our business activities and processes are engineered to make sure our customers have access to widest range of products with the shortest supply time lines. This achievement is made possible by our highly skilled and experienced team. We look for people who want to grow with us around the globe and stand out from the crowd. We now have people who embrace tomorrow, have vision, love stretching their minds and going far beyond what they thought was achievable.