China Wholesale Bohr atomic energy Factory – LADP-16 Apparatus for Determining Planck’s Constant – Advanced Model – Labor

Short Description:

LMEC-21 uses steel string and oscilloscope to measure the standing wave and vibration of uniform string, and can expand innovative experiments, this instrument needs self-prepared oscilloscope.
LMEC-21A is a cheaper version which don't need oscilloscope, The purpose of the instrument is to set up interesting string sound experiments. It can not only do the traditional basic string vibration experiment, but also expand to the applied experiment to calibrate the intonation of string instruments and learn the working principle of string instruments.


Product Detail

Product Tags

Related Video

Feedback (2)

We constantly continually give you essentially the most conscientious client provider, plus the widest variety of designs and styles with finest materials. These initiatives include the availability of customized designs with speed and dispatch for Newton, Fraunhofer Diffraction, Millikan"s Oil Drop, We give priority to quality and customer satisfaction and for this we follow stringent quality control measures. We have in-house testing facilities where our products are tested on every aspect at different processing stages. Owning to latest technologies, we facilitate our customers with customized production facility.
China Wholesale Bohr atomic energy Factory – LADP-16 Apparatus for Determining Planck’s Constant – Advanced Model – Labor Detail:

Planck’s Constant Experimental System applies the photoelectric effect to measure the current-voltage (I-V) characteristic curves of a photocathode against monochromatic light at different frequencies.

Experiment Examples

1. Measure I-V characteristic curve of a photoelectric tube

2. Plot U- curves

3. Calculate the follows:

a) Planck’s constant h

b) Cut-off frequency ν of cathode material of a photoelectric tube

c) Work function Ws

d) Verify Einstein’s equation

Specifications

Description

Specifications

Light Source Tungsten-halogen lamp: 12V/75W
Spectral Range 350~2500nm
Grating monochromator
Wavelength range 200 ~ 800nm
Focal length 100mm
Relative aperture D/f = 1/5
Grating 1200l/mm  (blazed@500nm)
Wavelength accuracy ±3nm
Wavelength repeatability ±1nm
Photoelectric Tube
Working voltage -2~ 40V continuously adjustable, 3-1/2 digital display
Spectral range 190~700nm
Peak wavelength 400±20nm

Product detail pictures:

China Wholesale Bohr atomic energy Factory –  LADP-16 Apparatus for Determining Planck’s Constant – Advanced Model – Labor detail pictures


Related Product Guide:

We provide fantastic energy in top quality and advancement,merchandising,gross sales and marketing and operation for China Wholesale Bohr atomic energy Factory – LADP-16 Apparatus for Determining Planck’s Constant – Advanced Model – Labor , The product will supply to all over the world, such as: Myanmar, Estonia, New Orleans, We only supply quality products and we believe this is the only way to keep business continue. We can supply custom service too such as Logo, custom size, or custom products etc that can according to customer's requirement.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Harriet from Sri Lanka - 2018.07.12 12:19
    Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Edward from Peru - 2018.08.12 12:27
    Write your message here and send it to us